Modellkennung LL | Artikel-Nr. LL | Leistungserklärung LL |
---|---|---|
CAQ450-R-ST-ERV-GB - Zehnder ComfoAir Q450 with Enthalpy Exchanger | 471502022 | 1603044Q45110.pdf(48 KB) |
Steuerung LL | Energieeffizienzklasse LL | Energieeffizienz-Label LL |
Energy Label – Central demand control | GB-EU-label_CAQ450ERV_471502022_A.pdf(141 KB) | |
Energy Label – Manual control | GB-EU-label_CAQ450ERV_471502022_A.pdf(141 KB) | |
Energy Label – Local demand control | EU-label_CAQ450ERV_471502022_A+.pdf(97 KB) | |
Energy Label – Clock control | GB-EU-label_CAQ450ERV_471502022_A.pdf(141 KB) |
Label | Value |
---|---|
Catalogue number | 471502022 |
GTIN | 8717573874427 |
Production model | COMFOAIR Q450 GB ST ERV |
Air flow rate | 450 m³/h |
Amperage | 2.2 A |
Supply voltage | 230 V |
Frequency | 50 Hz |
Noise/Sound Level | 45 |
Energy class I | A |
Energy class II | A+ |
With volatile organic compound (VOC) sensor | |
Housing material | Steel |
Material heat exchanger | Other |
Housing material quality | Other |
Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
Connections outdoor air side | Insert-/duct end |
Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
With bypass | |
Housing material | Steel coated |
Type of speed control | Other |
Max. air volume at 100 Pa | 450 m³/h |
Suitable for wall mounting | |
Nominal duct diameter | 180-200 mm |
With thermal overload protection | |
Type of motor | Electronically commutated (EC) |
Supporting protocol for Modbus | |
Material heat exchanger | Other |
Suitable for floor mounting | |
Suitable for (extra) carbon dioxide (CO2) sensor | |
Width | 725 mm |
Residential connection, top | |
Width | 725 mm |
Type of motor | Electronically commutated (EC) |
Power consumption at max. air volume at 100 Pa | 0.143 kW |
Energy efficiency class | A |
Suitable for zone controller | |
With constant pressure control | |
Voltage | 230 V |
Suitable for central heating boiler connection | |
Width | 725 mm |
Thermal efficiency at 70 % air volume at 50 Pa | 82 % |
Frequency | 50 Hz |
Depth | 570 mm |
Max. air volume at 200 Pa | 450 m³/h |
Frequency | 50 Hz |
Roof connection, side | |
Max. air volume at 150 Pa | 450 m³/h |
Suitable for ceiling mounting | |
Residential connection, left side | |
Left/right orientation reversible | |
Residential connection, underside | |
Number of phases | 1 |
Residential connection, right side | |
Heat recovery by | Cross-counter-flow unit |
Suitable for wireless remote control | |
Housing material quality | Other |
Max. air volume at 50 Pa | 315 m³/h |
Cos phi according to EPN standard | 0.48 |
Electrical connection | Connecting cable with plug with protective contact |
Suitable for wired control unit | |
Thermal efficiency according to EPN standard | 82 % |
Suitable for extra VOC sensor | |
Power input according to EPN standard | 0.115 kW |
With heating element | |
Type of frost protection | Other |
With bypass | |
With internal carbon dioxide (CO2) sensor | |
Suitable for wall mounting | |
Electrical connection | Connecting cable with plug with protective contact |
With thermal overload protection | |
Nominal duct diameter | 180-200 mm |
Suitable for floor mounting | |
Depth | 570 mm |
Suitable for central heating boiler connection | |
Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
Max. air volume at 100 Pa | 450 m³/h |
Suitable for (extra) carbon dioxide (CO2) sensor | |
Suitable for wireless remote control | |
Roof connection, top | |
Residential connection, left side | |
Roof connection, side | |
Residential connection, underside | |
Residential connection, top | |
Residential connection, right side | |
With digital display | |
Max. air volume at 150 Pa | 450 m³/h |
Weight | 49 kg |
Max. air volume at 200 Pa | 450 m³/h |
Height | 850 mm |
Depth | 570 mm |
With digital display | |
Supply filter according to ISO 16890-1:2016 | ISO Coarse |
Roof connection, top | |
Height | 850 mm |
Operation by app | |
Voltage | 230 V |
Heat recovery by | Cross-counter-flow unit |
Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
Voltage | 230 V |
Weight | 49 kg |
Suitable for ceiling mounting | |
With internal humidity (RH) sensor | |
Left/right orientation reversible | |
Suitable for (extra) humidity (RH) sensor | |
Power consumption at max. air volume at 100 Pa | 0.143 kW |
Frequency | 50 Hz |
Energy efficiency class according to 1253/2014/EU | A |
With constant pressure control | |
Electrical connection | Connecting cord with plug with protective contact |
With constant volume flow control | |
Housing material | Steel |
Type of frost protection | Other |
Suitable for extra VOC sensor | |
Connections residential side | Insert-/duct end |
Energy efficiency class according to 1253/2014/EU | A |
Connections outdoor air side | Insert-/duct end |
Max. air volume at 50 Pa | 315 m³/h |
Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
Electrical connection | Connecting cord with plug with protective contact |
Nominal duct diameter | 180-200 mm |
With internal carbon dioxide (CO2) sensor | |
With heating element | |
Type of motor | Electronically commutated (EC) |
Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
With zone controller | |
With wired control unit | |
With wired control unit | |
Supply filter according to ISO 16890-1:2016 | ISO Coarse |
With volatile organic compound (VOC) sensor | |
Suitable for (extra) humidity (RH) sensor | |
Degree of protection (IP) | IP40 |
With internal humidity (RH) sensor | |
Fuse size of the device | 16 A |
Degree of protection (IP) | IP40 |
Supporting protocol for Modbus | |
Fuse size of the device | 16 A |
With constant volume flow control | |
Suitable for zone controller | |
Connections residential side | Insert-/duct end |
With zone controller | |
Voltage | 230 V |
Suitable for wired control unit | |
Number of phases | 1 |
Height | 850 mm |
Nominal duct diameter | 180-200 mm |
Thermal efficiency at 70 % air volume at 50 Pa | 82 % |
Operation by app | |
Weight | 49 kg |
Fuse size of the device | 16 A |