Comfo Air Flex, perspective view,
Article no. 471234220

Zehnder ComfoAir Flex 250

  • Multiple installation options
  • Space saving design
  • Energy efficient

Declaration

Modellkennung LLArtikel-Nr. LLLeistungserklärung LL
CAF250-HRV-UK - Zehnder ComfoAir Flex 250471234220 2304044F25001.pdf(72 KB)
   
Steuerung LLEnergieeffizienzklasse LLEnergieeffizienz-Label LL

Data Table

LabelValue
Catalogue number 471234220
GTIN 8717573040891
Production model COMFOAIR FLEX 250 HRV ZGUK
Air flow rate 250 m³/h
Supply voltage 230 V
Frequency 50 Hz
Noise/Sound Level 42
Energy class I A+
Energy class II A
Suitable for extra VOC sensor
Suitable for wired control unit
Residential connection, left side
Width 1068 mm
Efficiency exhaust filter according to ISO 16890-1:2016 55 %
Depth 868 mm
Suitable for zone controller
Type of frost protection Heating element
Housing material Steel coated
Voltage 230 V
Material heat exchanger Other
Housing material quality Expanded polypropylene (EPP)
Roof connection, top
Electrical connection Connecting cord with plug with protective contact
Max. air volume at 50 Pa 150 m³/h
Suitable for ceiling mounting
Fuse size of the device 12.5 A
Left/right orientation reversible
Max. air volume at 150 Pa 200 m³/h
Supply filter according to ISO 16890-1:2016 ISO Coarse
Operation by app
Voltage 230 V
Nominal duct diameter 160-160 mm
Exhaust filter according to ISO 16890-1:2016 ISO Coarse
Suitable for wall mounting
Material heat exchanger Other
Exhaust filter according to ISO 16890-1:2016 ISO Coarse
Nominal duct diameter 160-160 mm
Weight 38 kg
Energy efficiency class according to 1253/2014/EU A+
Efficiency supply filter according to ISO 16890-1:2016 65 %
With thermal overload protection
Suitable for wireless remote control
Suitable for wall mounting
Residential connection, top
Connections residential side Insert end
Suitable for ceiling mounting
Connections outdoor air side Insert end
Number of phases 1
With bypass
Housing material Steel
Housing material quality Expanded polypropylene (EPP)
Energy efficiency class according to 1253/2014/EU A+
With heating element
Type of motor Electronically commutated (EC)
With wired control unit
Supporting protocol for Modbus
Suitable for (extra) humidity (RH) sensor
Connections outdoor air side Insert end
With internal humidity (RH) sensor
Max. air volume at 100 Pa 250 m³/h
Degree of protection (IP) IP20
Max. air volume at 200 Pa 250 m³/h
With zone controller
Thermal efficiency at 70 % air volume at 50 Pa 93 %
Suitable for floor mounting
Power consumption at max. air volume at 100 Pa 0.119 kW
Efficiency supply filter according to ISO 16890-1:2016 65 %
Power input according to EPN standard 0.119 kW
Suitable for (extra) carbon dioxide (CO2) sensor
Suitable for zone controller
Type of motor Electronically commutated (EC)
Suitable for central heating boiler connection
Frequency 50 Hz
Roof connection, top
Nominal duct diameter 160-160 mm
Roof connection, side
Supply filter according to ISO 16890-1:2016 ISO Coarse
With internal carbon dioxide (CO2) sensor
Height 327 mm
Residential connection, left side
Suitable for floor mounting
Residential connection, underside
Width 1068 mm
Residential connection, top
Suitable for (extra) carbon dioxide (CO2) sensor
Residential connection, right side
Frequency 50 Hz
Suitable for wireless remote control
With digital display
Width 1070 mm
Residential connection, underside
With digital display
Residential connection, right side
Depth 870 mm
Roof connection, side
Weight 38 kg
Voltage 230 V
With volatile organic compound (VOC) sensor
Left/right orientation reversible
Suitable for extra VOC sensor
Type of motor Electronically commutated (EC)
Efficiency exhaust filter according to ISO 16890-1:2016 55 %
Heat recovery by Cross-counter-flow unit
Height 327 mm
With volatile organic compound (VOC) sensor
Supporting protocol for Modbus
With thermal overload protection
Frequency 50 Hz
Suitable for central heating boiler connection
Number of phases 1
Electrical connection Connecting cable with plug with protective contact
Housing material Steel
With zone controller
Heat recovery by Cross-counter-flow unit
With wired control unit
With constant volume flow control
Degree of protection (IP) IP20
Fuse size of the device 12.5 A
With heating element
Electrical connection Connecting cord with plug with protective contact
With constant volume flow control
Max. air volume at 100 Pa 250 m³/h
Connections residential side Insert end
Type of frost protection Heating element
Voltage 230 V
Suitable for wired control unit
With internal carbon dioxide (CO2) sensor
Max. air volume at 50 Pa 150 m³/h
With constant pressure control
Max. air volume at 200 Pa 250 m³/h
Thermal efficiency at 70 % air volume at 50 Pa 93 %
Max. air volume at 150 Pa 200 m³/h
Cos phi according to EPN standard 0.39
Depth 868 mm
Power consumption at max. air volume at 100 Pa 0.119 kW
Height 327 mm
Energy efficiency class A+
With bypass
Thermal efficiency according to EPN standard 93 %
Weight 38 kg
With constant pressure control
With internal humidity (RH) sensor
Electrical connection Connecting cable with plug with protective contact
Suitable for (extra) humidity (RH) sensor
Operation by app
Nominal duct diameter 160-160 mm
Fuse size of the device 12.5 A

Downloads

loading...
Any questions? Please send us a message.

General Request

Contact Form

Offer Request

Contact Form

Order Request

Contact Form
Any questions? Feel free to give us a call.

General Request